Schneider Monitoring 24V AC DC XPS Emergency Stop Safety Relay
Schneider Electric Monitoring Safety Relay 24V DIN Rail 1.5 A Screw Tyep
Schneider waterproof Unmonitored 8a 5v 12v ac dc thermal electric Relay
Schneide ip20 ip40 Configurable industrial Miniature 50hz 60hz automotive parts
range of product
|
Preventa Safety automation
|
product or component type
|
Preventa safety module
|
safety module name
|
XPSAK
|
safety module application
|
For emergency stop, switch, sensing mat/edges or safety light curtain monitoring
|
function of module
|
Proximity sensor monitoring
Emergency stop monitoring 1-channel wiring Monitoring of electro-sensitive protection equipment (ESPE) Multiple emergency stop monitoring 2-channel wiring Monitoring of a movable guard Sensing mat and edges monitoring Emergency stop with 2 NC contacts monitoring 2-channel wiring Monitoring of a movable guard associated with 2 switches and automatic start |
safety level
|
Can reach PL e/category 4 conforming to EN/ISO 13849-1
Can reach SILCL 3 conforming to EN/IEC 62061 |
safety reliability data
|
DC > 99 % conforming to EN/ISO 13849-1
MTTFd = 154.5 years conforming to EN/ISO 13849-1 PFHd = 7.39E-9 1/h conforming to EN/IEC 62061 |
type of start
|
Configurable
|
connections - terminals
|
Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid with cable end, with double bezel Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid with cable end, with double bezel Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel |
output type
|
Relay instantaneous opening, 3 NO circuit(s), volt-free
|
number of additional circuits
|
1 NC + 4 solid state outputs
|
[Us] rated supply voltage
|
24 V AC - 15...10 %
24 V DC - 15...10 % |
synchronisation time between inputs
|
Unlimited (manual start)
2 or 4 s depending of wiring (automatic start) |
supply frequency
|
50/60 Hz
|
maximum power consumption in VA
|
5 VA AC
|
input protection type
|
Internal, electronic
|
[Uc] control circuit voltage
|
24 V DC
|
maximum line resistance
|
28 Ohm
|
breaking capacity
|
180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output |
breaking capacity
|
1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
|
output thermal current
|
6 A per relay for relay output
|
[Ith] conventional free air thermal current
|
18 A
|
associated fuse rating
|
4 A gG or gL for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
minimum output current
|
10 mA for relay output
|
minimum output voltage
|
17 V for relay output
|
maximum response time on input open
|
40 ms
|
[Ui] rated insulation voltage
|
300 V (pollution degree 2) conforming to IEC 60947-5-1
300 V (pollution degree 2) conforming to DIN VDE 0110 part 1 |
[Uimp] rated impulse withstand voltage
|
4 kV overvoltage category III conforming to IEC 60947-5-1
4 kV overvoltage category III conforming to DIN VDE 0110 part 1 |
local signalling
|
4 LEDs
|
current consumption
|
30 mA at 24 V AC on power supply
|
mounting support
|
35 mm symmetrical DIN rail
|
net weight
|
0.3 kg
|
standards
|
EN/ISO 13850
EN 1088/ISO 14119 EN/IEC 60947-5-1 EN/IEC 60204-1 |
product certifications
|
CSA
UL TÜV |
IP degree of protection
|
IP20 (terminals) conforming to EN/IEC 60529
IP40 (enclosure) conforming to EN/IEC 60529 |
ambient air temperature for operation
|
-10…55 °C
|
ambient air temperature for storage
|
-25…85 °C
|